Microscan MS-4X Manual de usuario Pagina 131

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 312
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 130
Chapter 7 Calibration Database
MS-880 Industrial Long Range Scanner User’s Manual 7-5
7–Calibration Data-
Save Current Settings to Configuration Database
Load Current Settings from Configuration Database
Request Database Settings
Returns settings for selected Configuration Database Index. Sending <K227?,1> will
return the record for the first database index, for example:
Sending <K227?> Returns settings for the entire Configuration Database in the fol-
lowing format:
The configuration database allows the user to save multiple scanner configuration set-
tings. The database can be used simply to save most commonly used scanner config-
urations to allow scanner to be easily adaptable to changing applications, or used in
conjunction with the Optoelectric Control, to dynamically change configurations.
Definition: Saves current settings to the configuration database index.
Serial Cmd: <K227+,database index>
Options: 1 to 7
Definition: Loads a specific database index.
Serial Cmd: <K227-,database index>
Options: 1 to 7
Definition: Associates a specific tracking setting with a database index.
Serial Cmd: <K227?,database index>
Options: 1 to 7
Vista de pagina 130
1 2 ... 126 127 128 129 130 131 132 133 134 135 136 ... 311 312

Comentarios a estos manuales

Sin comentarios