Sequence On Mismatch
6-8 MS-9 Scanner User’s Manual
Sequence On Mismatch
Note: Matchcode must be set to Sequential for this command to function.
As an example of Sequence On Mismatch Enabled, consider the following decodes:
1
As an example of Sequence On Mismatch Disabled, consider the following decodes:
You can access Master Symbol Database operations from the Utilities menu.
Usage: Enable this parameter if every trigger event should have a decode and
more than one consecutive mismatch may occur.
Disable this parameter if every trigger event should have a decode but no
more than one consecutive mismatch may occur.
Definition: When set to Enabled, the master symbol sequences on every decode,
match or mismatch. When set to Disabled, the master symbol will not
sequence whenever consecutive mismatches occur.
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card,sequence on noread,sequence on mismatch>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Master Symbol Decoded Symbol Master After Decode Action
001 001 002 Sequenced on match
002 abc 003 Sequenced on mismatch
003 def 004 Sequenced on mismatch
004 005 006 Sequence skipped
006 ghi 007 Sequenced on mismatch
007 007 008 Sequenced on match
1. In both tables, when the expected number is missed by only 1, the sequence skips over the
next number in order to resume the sequence.
Master Symbol Decoded Symbol Master After Decode Action
001 001 002 Sequenced on match
002 abc 003
Sequenced because of
previous match
003 def 003 Not sequenced
003 003 004 Sequenced on match
004 005 006 Sequence skipped
006 006 007 Sequenced on match