Copyright ©2010 Microscan Systems, Inc. 11
MS-820-to-QX-830 Compact Industrial Scanner Transition Guide
MS-820 and QX-830 Connectivity
There are significant hardware and connectivity differences between the MS-820 and QX-830. The diagrams
and parts list below demonstrate the difference between MS-820 and QX-830 hardware configuration.
Note: For other configurations, such as multidrop and daisy chain, refer to the configuration guides and
user’s manuals for the MS-820 and QX-830.
Item Description Part Number
1 MS-820 Industrial Laser Scanner FIS-0820-XXXXG
2 QX-830 Compact Industrial Scanner FIS-0830-XXXXG
3 IB-131 Kit, Interface Box and IB-131 cable, 6 ft. 98-000014-02
4 QX-1 Interface Device 98-000103-01
5 Power Supply, 90-264 VAC, 24VDC, USA/Euro plug 97-100004-15
6 QX Power Supply, M12 12-pin Socket, 1.3 m 97-000003-01
7 Object Detector Photo Sensor, Visible, NPN, Dark On 99-000017-01
8 QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m 99-000020-02
9 Communication Cable, 25-pin plug to 9-pin socket, 6 ft. 61-300026-03
10 QX Cordset, M12 12-pin plug and M12 12-pin socket to IB-131, RS-232, 2 m 61-000159-03
11 QX Cordset, M12 12-pin plug and M12 12-pin socket to IB-131, RS-422/485, 2 m 61-000159-04
12 QX Cordset, Common, M12 12-pin Plug to M12 12-pin Socket, 1 m 61-000162-01
13 QX Cordset, Host, Serial, M12 12-pin Plug to DB9, 1 m (not shown) 61-000152-01
14 QX Cordset, Host, Serial, M12 12-pin Socket to DB9, 1 m 61-000153-01
15 QX Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m 61-000160-01
16 QX Cordset, M12 12-pin Plug to MS-Connect 5100, 3 m (not shown) 61-000161-01
17
QX Cordset, M12 12-pin Plug/M12 12-pin Socket to MS-Connect 210, RS-232, 2 m (not shown)
61-000158-03
18
QX Cordset, M12 12-pin Plug/M12 12-pin Socket to MS-Connect 210, RS-422/485, 2 m (not shown)
61-000158-04
MS-820 Standalone with IB-131 QX-830 Serial Standalone with IB-131
A QX-830 can be connected to an IB-131
Interface Box using the RS-232 M12 to 15-pin
Dsub cordset (10) or the RS-422/485 M12 to
15-pin Dsub cordset (
11
). The RS-232 cordset
(10) is for RS-232 and AUX. The RS-422/485
cordset (
11
) does not support RS-232, regardless
of individual scanner command settings.
1
2
3
57
9
3
9
68
10 or 11
QX-830 Serial Standalone with QX-1 QX-830 Ethernet Standalone with QX-1
2
2
4
4
8
86
6
12
12
15
14
For Assistance, contact the Automation Group at Cross 800.866.4568