Imager Field of View and Resolution
Getting Started
1
Rev 2.0.0, Jan 2009 HawkEye™ 45T User Manual 1-37
Imager Field of View and Resolution
The HE45T’s megapixel imager, with a dual field optical system, can provide
you the best image for 1-D and 2-D applications.
The 1.3 Million Pixel imager is divided into near field and far field decode zones.
In each zone, the resolution is 1024 x 640 pixels (see Figure 1.25). In this mode
of operation the reader utilizes the highest resolution creating the widest working
range on bar code and 2-dimensional symbols of all densities. The trade-off is the
amount of time the reader spends processing the image. This time can be reduced
by optimization functions:
• If only the near field is used (small, high density symbols), the far field
image can be ignored.
• If only the far field is used (large, lower density symbols), the near field can
be ignored.
Further optimization may be obtained by “windowing” the field to a smaller area.
FIGURE 1–39. SXGA Imaging Area
1024
640
640
Far
Near