Rev 2.0.0, Jan 2009 HawkEye™ 45T User Manual 6-1
6
Advanced Decoder
Performance
6
CHAPTER 6 Advanced Decoder
Performance
Turbo Dot Peen Mode Settings
The HE45T with the default settings offers the best overall performance for Data
Matrix DPM reading. For reading dot peen marks with cell size larger than 15
mils or 0.015 inches, it is often possible to improve the reading performance by
enabling the Turbo Dot Peen mode. It is also recommended that you use Read
With Near Field Only mode in conjunction with the Turbo Dot Peen On mode to
achieve the best reading response.
Note: Turbo Dot Peen mode should not be used for reading small marks (dot
peen or others) as it may increase the processing time and reduce the robustness
of reading small marks.