Chapter 8 Data Outputs
MS-3 Laser Scanner User’s Manual 8-11
8–Data Outputs
Serial Verification
Serial Command Echo Status
Serial Command Beep Status
Definition: Allows the user to verify configuration command status.
Usage: These commands are useful in removing any doubt about the scanners
acceptance and response to host configuration commands.
For example, if the current preamble is “SOM” and <Kd1, START> is
entered, the scanner will echo back <Kd1, SOM> since the attempted
entry “START” exceeds the four character limit for that command.
Therefore it is rejected and the existing “SOM” message is echoed back
and remains the preamble message.
Definition: When enabled, a configuration command
received from the host is echoed back to
the host with the resultant settings.
Function: If a command with multiple fields is processed, some of the fields may
have been processed properly while others were not. The changes will
appear in the string echoed back so that the user will know which fields
did or did not change.
Serial Cmd: <K701,serial command echo status,serial command beep sta-
tus,control/hex output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Causes the scanner to beep once whenever a K command is entered to
indicate that the command was accepted and processed.
Function: If an invalid command is entered, the scanner beeps 5 times to indicate
an invalid entry. However, this does not necessarily mean that all data
fields have been entered incorrectly. Only one bad field needs to be
found in order to activate the 5 beep response.
Usage: Used to audibly verify the acceptance and validity of a command.
Scanner
Host