Chapter 5 Symbology
MS-3 Laser Scanner User’s Manual 5-23
5–Symbology
Application Record Padding (UCC/EAN-128)
Note: Output Format must be set to Application Record before this parameter can
take effect.
Definition: Padding is the insertion of zeros to make up the maximum length of a
variable application record data field, except for the last field which
does not require padding.
When enabled, padding is included. When disabled, padding is omitted.
Note: Padding is never added to fixed length fields or to the last data
field of a symbol. Enabling or disabling Record Padding will have no
effect on these.
Serial Cmd: <K474,,,,UCC/EAN-128 status,output format,application record sepa-
rator status,application record separator character,application record
brackets,application record padding>
Default: Disabled
Options: 0 = Disabled 1 = Enabled