MS-4X Imager User Manual
6-17
Symbologies
Symbol Length #1 (Interleaved 2 of 5)
Symbol Length #2 (Interleaved 2 of 5)
Usage: Useful in applications where I 2/5 symbols of a specific length are
required.
Definition: The Symbol Length # 1 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd: <K472,status,check character status,check character output,symbol length
#1,symbol length #2,guard bar status,range mode status>
Default: 16
Options: 0 to 64, even only
Important: If Range Mode is disabled, the length of the symbol must
match either Symbol Length # 1 or Symbol Length # 2 to be considered
a valid symbol.
If
Range Mode
is enabled,
Symbol Length # 1
and
Symbol Length # 2
form a range into which the length of the symbol must fall to be considered
valid.
Usage: Useful in applications where I 2/5 symbols of a specific length are
required.
Definition: The Symbol Length # 2 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd: <K472,status,check character status,check character output,symbol length
#1,symbol length #2,guard bar status,range mode status>
Default: 6
Options: 0 to 64, even only
Important: If Range Mode is disabled, the length of the symbol must
match either Symbol Length # 2 or Symbol Length # 1 to be considered
a valid symbol.
If
Range Mode
is enabled,
Symbol Length # 2
and
Symbol Length # 1
form a range into which the length of the symbol must fall to be considered
valid.