MS-4X Imager User Manual
4-13
Calibration
Calibration Progress Indicators
During the calibration process, the imager has a number of ways to communicate its prog-
ress to the user. The following three types of feedback are the primary ways that the
imager communicates calibration progress.
Read Rate LEDs
When calibration is initiated through a serial command or the EZ Button, the imager’s
Read Rate LEDs indicate calibration progress as follows:
Beeper/Green Flash
The beeper and green LED flash are used to indicate calibration status as shown in the
table below:
LEDs Calibration Progress
20% Search Pass in progress.
20%, 40% Focus Pass in progress.
20%, 40%, 60% Medium Pass in progress.
20%, 40%, 60%, 80% Fine-Tune Pass in progress.
20%, 40%, 60%, 80%, 100% Calibrated Successfully (holds for green flash duration).
Indicator Status
2 quick beeps Calibration has started.
5 quick beeps Calibration has failed.
1 long beep Calibration has been completed successfully.
1 sec. Green Flash Calibration has been completed successfully.