I/O Parameters
Control/Hex Output
Usage:
Useful for viewing settings with binary characters when using serial commands
on a terminal.
Definition: Determines the response to a Serial Command Echo or status request
command.
When set to
Control
, two characters are transmitted to represent a non-displayable
character. For example, a carriage return will be shown as: ^M.
Serial Cmd: <K701,serial command echo status,serial command beep status,control/hex
output>
Default: Control
Options: 0 = Control 1 = Hex