MS-4Xi Imager User Manual
7-45
I/O Parameters
No Read
Outputs the first No Read image in the read cycle. The image file will immediately follow
the symbol data.
Note: If two symbols are present in the same image capture and one of them is successfully
decoded, no image will be output.
No Read and Good Read
Outputs the first No Read or Good Read image in the read cycle.
Mismatch
Outputs the image of the first mismatch condition.
Image Format
Lossless
A “lossless” image is one that is in a high resolution format, and that will not lose resolution
even when manipulated and saved multiple times. When Lossless is enabled, the JPEG
Quality setting has no effect.
Compressed
Outputs the image in JPEG format. Image quality is determined by the JPEG Quality
setting.
JPEG Quality
Definition: Selects the format of the image output file.
Serial Cmd:
<
K757,
status,
comm port,image mode,
image format
,JPEG quality,object info
output
, grade output
>
Default: Compressed
Options: 0 = Lossless 1 = Compressed
Definition: Sets the amount of JPEG image compression. A value of 1 represents the
highest compression and lowest image quality, and 100 represents the
lowest compression and highest image quality.
Serial Cmd:
<
K757,
status,comm port,image mode,image format,
JPEG quality
,object info
output
, grade output
>
Default: 90
Options: 1 to 100 (percent)