5-3
Read Cycle
Read Cycle Serial Commands
Trigger Mode/Filter Duration
<K200,trigger mode,leading edge trigger filter,trailing edge
trigger filter>
Serial Trigger Character <K201,serial trigger character>
External Trigger State <K202,external trigger state>
End of Read Cycle <K220,end of read cycle,read cycle timeout>
Minimum Good Reads <K221,minimum good reads>
Multisymbol <K222,number of symbols,multisymbol separator>
Start Trigger Character <K229,start character>
Stop Trigger Character <K230,stop character>
Capture Timing <K242,time before first capture,time between first and second
captures,,,,,,,,time between seventh and eighth captures>
Image Storage <K244,image storage type,image store mode>
Image Processing Timeout <K245,image processing timeout>