Microscan MS-4Xi Manual de usuario Pagina 219

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 360
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 218
MS-4Xi Imager User Manual
9-5
Matchcode
Matchcode Type
Definition: Allows the user to choose the way that master symbols will be compared
with subsequently read symbols.
Note: First set Triggering Mode to External or Serial.
ESP:
Serial Cmd: <K223,matchcode type,sequential matching,match start position,
match length,wild card character,sequence on No Read,sequence on
mismatch>
Default: Disabled
Options: 0 = Disabled
1 = Enabled
2 = Wild Card
3 = Sequential
Disabled: Has no effect on operations.
Enabled: Instructs the imager to compare symbols or portions of symbols with the
master symbol.
Wild Card: Allows the user to enter user-defined wild card characters in the master
symbol.
Sequential: Instructs the imager to sequence after each match (numeric only) and
compare symbols or portions of symbols for sequential numbers.
Note: If Matchcode Type is set to Sequential, the imager will behave
as if Number of Symbols were set to 1, regardless of the user-defined
configuration.
Vista de pagina 218
1 2 ... 214 215 216 217 218 219 220 221 222 223 224 ... 359 360

Comentarios a estos manuales

Sin comentarios