MS-4 Imager User’s Manual 6-15
Symbologies
Symbol Length #1 (Interleaved 2 of 5)
Symbol Length #2 (Interleaved 2 of 5)
Usage: Useful in applications where I 2/5 symbols of a specific length are required.
Definition: The Symbol Length # 1 field is one of two fields against which the decoded
symbol is compared before accepting it as valid or rejecting it.
Serial Cmd: <K472,status,check digit status,check digit output,symbol length #1,symbol
length #2,guard bar status,range mode status>
Default: 10
Options: 0 to 64, even only.
Important: If Range Mode is disabled, the length of the symbol must match
either Symbol Length # 1 or Symbol Length # 2 to be considered a valid
symbol.
If
Range Mode
is enabled,
Symbol Length # 1
and
Symbol Length # 2
form
a range into which the length of the symbol must fall to be considered valid.
Usage: Useful in applications where I 2/5 symbols of a specific length are required.
Definition: The Symbol Length # 2 field is one of two fields against which the decoded
symbol is compared before accepting it as valid or rejecting it.
Serial Cmd: <K472,status,check digit status,check digit output,symbol length #1,symbol
length #2,guard bar status,range mode status>
Default: 6
Options: 0 to 64, even only.
Important: If Range Mode is disabled, the length of the symbol must match
either Symbol Length # 2 or Symbol Length # 1 to be considered a valid
symbol.
If
Range Mode
is enabled,
Symbol Length # 2
and
Symbol Length # 1
form
a range into which the length of the symbol must fall to be considered valid.