Microscan MS-4 Manual de usuario Pagina 163

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 390
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 162
MS-4 Imager User’s Manual 7-7
I/O Parameters
Linear Symbols:
1. Failed user defined minimum number of bars.
2. Failed to decode start/stop character (doesn’t apply to UPC, GS1 DataBar, or
MicroPDF417).
3. Failed user defined minimum number of scan lines that qualify for the minimum
number of bars.
4. Failed to decode.
5. Failed to decode UPC supplemental.
No Read Message
Note: No Read Message will only be transmitted if Symbol Data Output is set to Match,
Mismatch, or Good Read.
No Read Message can be set to any ASCII character.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K714h,,3C>
For >: <K714h,,3E>
For
, : <K714h,,2C>
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to
enter ASCII characters as hex values.
Definition: Any combination of ASCII characters can be defined as the No Read
message.
Serial Cmd: <K714,No Read message status,No Read message>
Default: No Read
Options: A string of up to 64 ASCII characters.