Microscan MS-4 Manual de usuario Pagina 303

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 390
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 302
MS-4 Imager User’s Manual 13-7
Utilities
Device Control
Device Control by ESP
Device Control by Serial Command
Output 1 Pulse
Sending <L1> activates the link between Output 1 (+) and Output 1 (-) of the host connector
(regardless of Master Symbol or Output 1 status).
Output 2 Pulse
Sending <L2> activates the link between Output 2 (+) and Output 2 (-) of the host connector
(regardless of Master Symbol or Output 2 status).
Output 3 Pulse
Sending <L3> activates the link between Output 3 (+) and Output 3 (-) of the host connector
(regardless of Master Symbol or Output 3 status).
Disable Imager
Sending <I> will turn the Imager OFF, end the current read cycle, and will not allow the
Imager to enter another read cycle until turned ON. This feature is useful during extended
periods of time when no symbols are being decoded, or the Imager is being configured.
Disabling the Imager will not affect any commands that have already been downloaded.
Enable Imager
Sending <H> will turn the Imager ON and allow it to enter read cycles.
Enable PDF Information
Sending <a1> will cause PDF417 data to be prefaced with information consisting of error
correction level (ECC level n), number of rows (n rows), number of columns (n columns),
number of informative code words (n info code words), and the number of data characters
(n data bits). Send <a1> again to disable PDF Information.
Vista de pagina 302
1 2 ... 298 299 300 301 302 303 304 305 306 307 308 ... 389 390

Comentarios a estos manuales

Sin comentarios