7-20 MS-4 Imager User’s Manual
Output Indicators
Green Flash Duration
Usage: Provides visual verification that a good read has occurred.
Definition: When a good read occurs, the green LEDs will illuminate and stay on for
the time set in the Green Flash Duration value.
Serial Cmd: <K750,green flash mode,target pattern status,green flash duration>
Default: 100 (1 second)
Options: 0 to 65535 (in 10mS increments)