MS-4 Imager User’s Manual 10-7
Camera and IP Setup
Threshold (Histogram)
Enable Autothreshold is checked by default.
To adjust the threshold manually,
1. Uncheck the Enable Autothreshold box.
2. Move the threshold marker (vertical green dashed line) in the Histogram chart.
Hint: This should be midway between the maximum and minimum curves.
3. Click on the Send Threshold button to adopt the new threshold position.