Counters
11-4 MS-3 Laser Scanner User’s Manual
11–Utilities
Counters
Counter commands can be a numeric value from 00000 to 65,535. After reaching the
maximum numeric limit of 65,535, the counter will automatically roll-over and start
counting again at 00000. To obtain the cumulative total of counts after the roll-over
has occurred, add 65,536 per each roll-over (the scanner does not keep track of the
number of roll-overs) to the current count.
Note: All counter values will be lost if power is recycled to the scanner or the scanner
receives a reset or save command.
By Serial Command
Noread Counter
Sending <N> displays the total number of noreads that have occurred since the last reset.
Noread Counter Reset
Sending <O> sets Noread Counter to 00000.
Trigger Counter
Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset
Sending <U> sets the trigger counter to 00000.
Good Read/Match Counter
Sending <V> displays the total number of good reads matching the master symbol if
Matchcode is enabled. This counter is always enabled, but will only work as a match
count when Matchcode is enabled. If Matchcode is not enabled, this counter records
the number of good reads. This count can be requested at any time.
Good Read/Match Counter Reset
Sending <W> sets the match counter to 00000.
Mismatch Counter
With Matchcode enabled, sending <X> displays the number of decoded symbols
since the last reset that do not match the master symbol.
Mismatch Counter Reset
Sending <Y> sets the mismatch counter to zero.