External Trigger State
4-10 MS-3 Laser Scanner User’s Manual
4–Read Cycle/Trig-
External Trigger State
Note: External Level, External Edge, or Serial Data or Edge trigger mode must
be enabled for External Trigger to take effect.
Definition: Determines whether a positive or negative transition will initiate the
read cycle.
Usage: Users can select the trigger polarity that will operate with their sys-
tems. (If using the Microscan object detector, use Positive.)
Serial Cmd: <K202,external trigger state>
Default: Positive
Options: 0 = Negative 1 = Positive