Chapter 2 Communications
MS-3 Laser Scanner User’s Manual 2-13
2–Communications
Parity, Aux Port
Stop Bits, Aux Port
Data Bits, Aux Port
Definition: An error detection routine in which one data bit in each character is
set to 1 or 0 so that the total number of 1 bits in the data field is even
or odd.
Usage: Only changed if necessary to match host setting.
Default: Even
Options: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Serial Cmd: 0 = None
1 = Even
2 = Odd
Definition: Allows the user to select the last one or two bits in each character to
indicate the end of the character.
Usage: Only changed if necessary to match host setting.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Default: One
Options: 0 = One 1 = Two
Definition: Number of bits in each character.
Usage: Only changed if necessary to match host setting.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Default: Seven
Options: 0 = Seven 1 = Eight