Microscan MS-4 Especificaciones Pagina 65

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 202
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 64
Chapter 4 Read Cycle/Trigger
MS-3 Laser Scanner User’s Manual 4-17
4–Read Cycle/Trig-
Timeout Duration
Note: A minimum setting of 2 is recommended.
Note: Timeout or Timeout or New Trigger under End of Read Cycle must be
enabled for Timeout Duration to take effect.
Definition: Timeout Duration is the time span of the read cycle and is repre-
sented in 10 mS increments. It is used in conjunction with External
Edge or Serial Trigger.
Usage: It is useful in many tightly controlled applications which require a read
cycle to end before the next object appears and therefore need the
flexibility of a timeout adjustment.
Serial Cmd: <K220,end of read cycle,timeout duration>
Default: 100 (Corresponds to one second or 1000 mS.)
Options: 0 to 65535. (Divide any positive number entered by 100 to determine
the time in seconds.)
Vista de pagina 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 201 202

Comentarios a estos manuales

Sin comentarios