MS-2 CCD Reader User’s Manual 2-17
Using ESP
Defaulting
When you select Default Current Menu Settings or Default all ESP Settings, you are
only defaulting the ESP settings.
Advanced Options
Send Current View
This is the same as Save to
Reader > Send No Save except
that only the commands in the current
tree control are sent.
Send Current Command
Saves only the command that is
currently selected in the tree control.
Add/Remove Exception
After you perform a Receive Reader Settings command
1
and you click on the Advanced
Options > Add Exception option, you may see a list of serial commands. These are
commands that may be in your reader’s firmware but are not included in (or are different
from) your current version of ESP. When exceptions are present, the Exceptions button
will appear to the right of the other mode buttons (
Communication
,
Read Cycle
,
Symbologies
).
When no exceptions are present, the button will disappear.
You can edit exception commands by double-clicking on them and changing them as
needed.
It is important to note that these commands will be saved to your reader whenever you
send a Save to Reader command, or an <A> or <Z> command.
Also, if there is a corresponding ESP menu item, the ESP Value column for that item will
be blank following a Receive Reader Settings command.
1. From the Send/Recv button, or by right-clicking in any blank section of a tree control.