5-14 MS-2 CCD Reader User’s Manual
Plessey Code
Plessey Code
Status (Plessey Code)
Check Character Output Status (Plessey Code)
Minimum Symbol Length (Plessey Code)
Usage: Used primarily in library and retail applications.
Definition: Plessey Code consists of pairs of wide and narrow bars representing binary
data which, taken in units of 12, define hexadecimal characters.
Serial Cmd: <K487,status,check character output status,0,minimum symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: When this field is enabled, the check character will be output with symbol
data. When disabled, the check character will not be output with symbol
data.
Serial Cmd: <K487,status,check character output status,0,minimum symbol
length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition:
This field specifies the minimum number of characters the reader will recognize,
including a check character.
Serial Cmd: <K487,status,check character output status,0,minimum symbol length>
Default: 0
Options: 0 to 32