Microscan MS-2 Manual de usuario Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 125
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
MS-2 CCD Reader User’s Manual 5-9
Symbologies
Symbol Length #1 (Interleaved 2 of 5)
Symbol Length #2 (Interleaved 2 of 5)
Range Modes (Interleaved 2 of 5)
Variable Length
To set for any length, Symbol Length # 1 and Symbol Length # 2 must both equal zero.
Minimum Length
To set for minimum length, both Symbol Length # 1 and Symbol Length # 2 must be
equal to each other and be any number other than zero.
Fixed Length
To set for a fixed length, Symbol Length #1 and Symbol Length #2 must not be equal to
each other.
Usage: Useful in applications where I 2/5 symbols of a specific length are
required.
Definition: The Symbol Length # 1 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd: <K472,status,check character status,check character output,symbol length
#1,symbol length #2>
Default: 10
Options: 0 to 32
Usage: Useful in applications where I 2/5 symbols of a specific length are
required.
Definition: The Symbol Length # 2 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd: <K472,status,check character status,check character output,symbol length
#1,symbol length #2>
Default: 6
Options: 0 to 32
Vista de pagina 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 124 125

Comentarios a estos manuales

Sin comentarios