Chapter 8 I/0 Parameters
MS-9 Scanner User’s Manual 8-15
Trigger Evaluation Period
Note: For Trend Analysis to function the Number To Output On and the Trigger
Evaluation Period must be 1 or more.
Number to Output On
Note: For Trend Analysis to function the Number To Output On and the Trigger
Evaluation Period must be 1 or more.
Note: The number of matches, etc. for this setting does not need to be sequential.
Decodes per Trigger
Definition: The number of trigger events to examine within the trend analysis event.
Serial Cmd: <K810,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,decodes per trig-
ger>
Default: 0
Options: 0 to 255
Definition: Sets the number of events (matches, mismatches, noreads, etc. as con-
figured by Output On) that must occur before activating the associated
output.
Serial Cmd: <K810, output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,decodes per trig-
ger>
Default: 1
Options: 1 to 255
Definition: When Reads/Trigger trend analysis mode is enabled, the Reads per
Trigger Threshold value is the minimum number of successful reads
required during a read cycle.
Helpful
Hints:
You can determine the expected number of scans during a read cycle by
multiplying the enabled Number of Scans per second times the number
of seconds in the read cycle.
Serial Cmd: <K810,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,decodes per trig-
ger>
Default: 0
Options: 0 to 65,535