Chapter 6 Matchcode
MS-9 Scanner User’s Manual 6-7
Sequence On Noread
When Sequence On Noread is enabled, the master symbol will increment by one if
either a match or a noread occurs.
If both Sequence On Noread and Sequence On Mismatch are enabled, the master
symbol will increment in every event (match, mismatch, or noread).
In the special case, where the expected number is missed by only 1, the sequence skips
over the next number in order to resume the sequence. For example, a 002 is expected
but a 003 is read. The next master symbol will be 004.See the tables under
“Sequence
On Mismatch” on page 6-8 for examples of this.
Usage: Sequence On Noread is useful when the scanner needs to stay in
sequence even if no decode occurs.
Definition: When Sequence On Noread is Enabled and Matchcode is set to
Sequential, the scanner sequences on every match or noread. When
disabled, it does not sequence on a noread.
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on noread,sequence on mis
-
match>
Default: Enabled
Options: 0 = Disabled 1 = Enabled