Symbology Identifier
5-20 MS-9 Scanner User’s Manual
Symbology Identifier
Explanation of Modifiers for Code 39, Codabar, and I2/5
•For Code 39, Codabar and I 2/5, the modifier indicates Check Digit and Check
Digit Output status.
•For Code 39 only, Full ASCII needs to be enabled to see modifiers 4, 5, and 7.
Example:]A5 indicates a Code 39 symbol with Check Digit and Check Digit Output
enabled and Full ASCII conversion performed.
For Other Symbologies
For Code 128, a 1 indicates EAN; otherwise the modifier is a 0.
For all other symbologies, the modifier is 0.
Usage: Used when the symbology type and how it’s decoded needs to be known.
Definition: Symbology ID is an AIM standard prefix set of characters that identify the
symbol type.
When enabled, the scanner analyzes and identifies the symbology and
adds a three character identifying prefix to the data:
1. ] (close bracket character) indicating the presence of a symbology ID
2. A, C, E, I, L, Q, b, d, p
A = Code 39; C = Code 128; E = UPC/EAN; F = Codabar; G = Code
93; I = I–2/5
3. Modifier (see Explanation of Modifiers below)
Serial Cmd: <K450,narrow margins,symbology identifier status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Modifier Check Digit
Check Digit
Output
Full ASCII conversion performed
(Code 39 only)
0 Disabled N/A No
1 Enabled Enabled No
3 Enabled Disabled No
4 Disabled N/A Yes
5 Enabled Enabled Yes
7 Enabled Disabled Yes