Warning Messages
9-8 MS-9 Scanner User’s Manual
Laser Low
When enabled, a message is transmitted whenever the laser current falls below a fac-
tory-calibrated reference value which cannot be altered. The message repeats once
every 30 minutes until the condition is corrected.
Laser Low Status
Laser Low Message
Note: If you suspect that erroneous defaults are occurring, enable NOVRAM Mes-
sages by sending <K400,1,,,1>. This will allow the NOVRAM messages, if present, to
be viewed.
Usage: Alerts the user to impending laser failure. (Contact your service repre-
sentative.)
Definition: Enables the Laser Low message.
Serial Cmd: <K400,warning message status,laser high status,laser low status,
novram corrupt warning status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Defines the Laser Low message.
Serial Cmd: <K405,laser low message>
Default: LOW_LASER
Options: Any 1 to 10 character ASCII string except NUL, <, or >.