Appendices
MS-9 Scanner User’s Manual A-13
Appendix D — Serial Configuration Commands
The following table is a list of all the available serial configuration commands (also
called “K commands”). These commands are also listed at the beginning of each appli
-
cable chapter. For utility (operational) commands see Table 12-1, “Summary of Util-
ity Serial Commands,” on page 12-3.
Table A-8 Complete List of Serial Configuration Commands
Command Title
Legacy
cmds
Format
Communications
Host Port Parameters Ka <K100,baud,parity,stop bits,data bits>
Host Protocol Kf <K140, protocol>
Aux Port Parameters Ky
<K101, aux port mode,baud,parity,stop bits,data bits,daisy
chain status,daisy chain ID>
Daisy Chain Scanner ID <K151,daisy chain scanner,daisy chain scanner ID>
Preamble Kd <K141,status,preamble>
Postamble Ke <K142,status,postamble>
LRC Kc <K145, status>
Intercharacter Delay KB <K144, time interval>
Response Timeout KA <K143, timeout>
Network Client <K120, net port status>
Serial Gateway Configuration
<K125, length status,rx from network size,tx to network
size,pad status,pad char,begin/end justify data status,byte
swap status>
DeviceNet <K121, deviceNet baud rate,deviceNet address>
Profibus <K122, profibus station address>
DataHighway Plus <K123, DHP baud rate,DHP address>
Read Cycle
Multisymbol KL <K222, number of symbols,multisymbol separator>
Trigger Mode Kg <K200, trigger mode,trigger filter duration>
External Trigger State Kj <K202, external trigger state>
End of Read Cycle Kh <K220,end of read cycle mode,read cycle timeout>
Serial Trigger Character Ki <K201, character>
Good Decode Reads Km <K221, good decode reads>
Gain/Tracking KD <K504, gain,tracking>
Scan Speed <K500,scan speed>
Automatic Gain Control KH <K505, AGC sampling status,transition counter>
Video Settings KI
<K502, maximum element,video filter time,minimum
symbol transitions>
Symbologies
OMR Setup
<K490,status,parity status,# fields,trigger delay
mode,# scans,gate bar location,trigger delay type,out
-
put style>
OMR Calibration KP
<KPcalibrate delay status,auto frame status,avg bar
width,avg cell width,leading margin,scan count value>