Microscan MINI Hawk Xi Manual de usuario Pagina 296

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 388
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 295
13-12
MINI Hawk Xi High Performance Imager User Manual
Master Database
Enter Master Symbol Data
Usage: Allows you to enter master symbol data for any enabled master symbol index
number (1 to 10), provided the total number of characters does not exceed
the maximum allowed.
Serial Cmd: <K231,master symbol number,master symbol data>
Options: Enter data for 1 to 10 symbols (any combination of ASCII text up to the
maximum allowed.
For example, to enter data for master symbol 9, after making certain that
master
symbol database size is enabled for 9 or more symbols, send
<K231,9,data>
.
Important: The ASCII characters <, >, and , can only be entered as hex pairs.
Caution:
If no data is entered, the existing data will be deleted.
ESP: 1. Open the Utilities menu.
2. Set the number of master symbols you want to create in Master Symbol
Dat
abase Size.
3. Double-click on each symbol number you want to set up and copy, or type
your data in the popup dialog and click OK.
4. When all your data has been entered, click the Send Database to the
Reader butt
on.
Vista de pagina 295
1 2 ... 291 292 293 294 295 296 297 298 299 300 301 ... 387 388

Comentarios a estos manuales

Sin comentarios