
A-56 MINI Hawk Xi High Performance Imager User Manual
Allen-Bradley Version 20 PLC Setup, Trigger and Read
• Enter a specific name for the AOI element and click the Create button when done.
Repeat this step for the Assembly_Input and Assembly_Output.
• To link the connection input and outputs double-click the element and select the drop
down button. Locate the device and expand :I for inputs. Double-click :I:Data to complete
the link. Double-click the output connection and expand :O for outputs. Double-click
:I:Data to complete the link.
Comentarios a estos manuales