Microscan MINI Hawk Xi Manual de usuario Pagina 313

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 388
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 312
MINI Hawk Xi High Performance Imager Us
er Manual 14-3
Output Format
Output Format Status
Output Format Status Disabled
When Output Format Status is set to Disabled, output formatting is globally disabled.
Output Format Status Enabled
When Output Format Status is set to Enabled, output formatting is enabled. However,
Format Assign, Format Insert, and Format Extract must be properly set up as well.
Output Format Status by ESP
Definition: This is a global enable/disable parameter. In order to use formatting you
must set up the format using the insert and extract commands, and you
must also assign a symbol to format using the Format Assign command.
Serial Cmd: <K743,output format status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
On the Output Format tab, check the Enable Output Format box.
Vista de pagina 312
1 2 ... 308 309 310 311 312 313 314 315 316 317 318 ... 387 388

Comentarios a estos manuales

Sin comentarios