MINI Hawk Xi High Performance Imager Us
er Manual 5-11
Read Cycle
External Trigger Polarity
Usage: Allows users to select the trigger polarity that will be used in their application.
Definition: Determines the active state of the trigger signal applied to the cable input of
the imager.
Serial Cmd: <K202,active state>
Default: Positive
Options: 0 = Negative 1 = Positive