4-2
MINI Hawk Xi High Performance Imager User Manual
Calibration Serial Commands
Calibration Serial Commands
Calibration Overview
Autocalibration is one of the most powerful features of the MINI Hawk Xi. The calibration
process can be initiated by serial command, EZ button, or ESP user interface.
When the imager enters calibration, it runs through an optimization cycle that sets the ideal
parameters for reading symbols at the highest possible level of performance. Autocalibration
can be specially configured to optimize specific parameters, such as focus, gain, shutter
speed, and symbol type.
The calibration process consists of five separate phases: quick focus, search pass, focus
pass, medium pass, and fine-tune pass. During this process the imager quickly locates
configuration setup, defines a calibration range for the configuration parameters, and then
tunes those parameters for optimal performance.
Calibration Options <K529,gain,shutter speed,focus position,symbol type,WOI
framing,WOI margin,line scan height,processing>
Autocalibrate
<
@CAL
>