Install ESP
Save changes whenever you reconfigure Imager settings.
1-8 COPYRIGHT © 2005 MICROSCAN SYSTEMS
Save
Settings
Clear
all Data
Default
to USB
Clear XML
Rules
Default
to PS2
Install ESP
(ESP stands for Easy Setup Program.)
ESP is Microscan’s proprietary reader setup and testing software. It is not meant to be
a tool for a real-time production environment; the purpose of ESP is to provide a quick
and easy way to set up and configure your reader.
With your Imager connected to a host computer (Windows™98 or higher), you can use
ESP for configuration and Imager control.
1. Insert your “Microscan Tools” CD into your computer’s CD drive.
2. Launch Setup.exe under ESP and follow the prompts.
If downloading from the web:
a) Go to http://www.microscan.com/mymicroscan
b) Create a new “myMicroscan” member account or, if you are already a member,
enter your user name and password.
c) Follow the prompts in the Download Center and choose a download option (
ZIP
or
EXE
).
d) Extract the ESP files to a directory of your choice.
3. Note where your “ESP.exe” file is stored on your hard drive.
At the end of the installation process, you should see the following icon on your
desktop:
USB
Mode
RS-232
Mode
USB
RS-232
ESP supports only USB and RS-232 interfaces. The Imager must be in one
of the modes below to communicate with ESP. Bluetooth is not supported.