Batch/Battery
Save changes whenever you reconfigure Imager settings.
COPYRIGHT © 2005 MICROSCAN SYSTEMS 6-5
Save
Settings
Clear
all Data
Default
to USB
Clear XML
Rules
Default
to PS2
RS-232 Batch Features
RS-232 interfaces WILL NOT detect when an RS-232 cable is removed unless the power
adapter for the RS-232 cable is plugged in. If your power cable is unplugged, you may
still enter Batch Mode by scanning the RS-232 Batch symbol below.
However, when you return and re-connect to the RS-232 adapter you must enable
RS-232 Cabled to put the Imager back into Cabled Mode. In RS-232 Cabled the
Imager thinks it is always connected. It has no way to know (or check) if it is
unplugged. Therefore, data collected will be automatically sent out the disconnected
port, (i.e. it will not buffer the data -- it will only log it, assuming Send & Log Mode
is set). The data would be lost if the Imager were in Send & Buffer Mode.
The opposite is true for RS-232 Batch. In this mode the Imager assumes that it is
NOT cabled. It will buffer and log the data unless you plug it into the cable that has
a power adapter. In this exception the Imager can detect the power line and auto-
matically switch to “cabled operation”.
RS-232 Batch RS-232 Cabled