Vista de pagina 95
Match Length
6-6 MS-9 Scanner User’s Manual
Match Length
Wild Card
Usage: For example, if Match Length is set to 6 in a 10 character symbol, and
Match Start Position is set for 2, only the 2nd through 7th characters
(from left to right) will be compared.
Definition: Defines the length of the character string that will be compared with that
of the master symbol when Match Start Position is set to 1 or greater.
When Match Start Position is set to 0, no comparison will occur.
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on noread,sequence on mismatch>
Default: 1
Options: 1 to 64
Usage: For example, with Wild Card character defined as the default asterisk,
defining CR*34 as the master symbol will result in matches for CR134,
CR234, but not CR2345. Entering the wild card at the end of the master
symbol as in CR* will result in matches for variable symbol lengths such
as CR1, CR23, CR358, etc.
Definition: Wild Card character allows a user to define a wild card character as part
of the master symbol.
Serial Cmd: <K223 ,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on noread,sequence on mis
-
match>
Default: * (asterisk)
Options: Any valid ASCII character