Matchcode Type
7-8 MS-820 Industrial Bar Code Scanner User’s Manual
7–Matchcode
Sequence On Noread
As an example of Sequence on Noread Enabled, consider the following series of
decodes:
As an example of Sequence on Noread Disabled, consider the following series of
decodes:
Definition: When Sequence On Noread is Enabled and Matchcode is set to
Sequential, the scanner sequences the master label on every match or
noread. When disabled, it does not sequence on a noread.
Usage: Sequence On Noread is useful when the scanner needs to stay in
sequence even if no decode occurs.
Serial Cmd: <Knmatchcode type,sequential matching,match start position,
match length,wild card character,sequence on noread,sequence on
mismatch>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Master label Decoded label Master label after decode
001 001 002
002 002 003
003 noread 004 (sequenced on noread)
004 004 005
005 noread 006 (sequenced on noread)
006 noread 007 (sequenced on noread)
007 007 008
Master label Decoded label Master label after decode
001 001 002
002 002 003
003 noread 003 (not sequenced)
003 003 004
004 noread 004 (not sequenced)
004 noread 004 (not sequenced)
004 004 005