Defaulting/Saving/Initializing
MS-820 Industrial Bar Code Scanner User’s Manual A-23
Appendices
Initializing
Initializing is a part of all save and default functions. It is also used as a follow-on to
implement serial configuration commands into active memory.
Initializes serial configuration commands in
active memory and resets counters to zero.
Does not save settings to NOVRAM.
By Serial Command
Send <A> after a serial configuration command or
a string of serial configuration commands, for
example, <Kd1><A>.
By ESP
Right-click in the configuration window and select Save to Scanner, Send No Save.
This will initialize all serial configuration changes that have been made in the current
ESP session.
Loss of Communications
Making changes to communications with the host such as Baud Rate, Parity, Stop
Bits, LRC, etc. without corresponding changes in linked device(s) can result in the
loss of menu access through If this should occur, you should restore the scanner’s
defaults.