Chapter 9 Discrete I/0
MS-820 Industrial Bar Code Scanner User’s Manual 9-5
9–Discrete I/0
Active State
Pulse Width
Number Before Output
Definition: Sets the active state of the discrete output.
Serial Cmd: <Kvoutput on,active state,pulse width,number before output>
Default: Normally Open
Options: 0 = Normally Closed
1 = Normally Open
Definition: Sets the time in 10 mS increments that the discrete output remains
active.
Serial Cmd: <Kvoutput on,active state,pulse width,number before output>
Default: 5 (.05 seconds). Corresponds to 50 mS displayed in the menu.
Options: 1 to 255 (0.01 to 2.55 seconds). Divide the number entered on the
command line by 100 for time in seconds.
Definition: Sets the number of events (matches, mismatches, or noreads as con-
figured by Output On) that must occur before activating the associated
output.
Usage: For example, if Number to Output On is set to 3 and Output 1 is set to
Noread, then Output 1 will not be activated until 3 noreads have occurred.
Serial Cmd: <Kvoutput on,active state,pulse width,number before output>
Default: 0
Options: 0 to 255