10-2 MS-820 Industrial Bar Code Scanner User’s Manual
10–Diagnostics
Diagnostics by ESP Menu
Diagnostics by Serial Command
Command Title Cmds Format
Warning Message Status K”
<K”warning message status,laser high status,laser low
status,novram/reset warning status>
Lifetime Hours K$ <K$hours10,message>
Over-temperature K+ <K+degrees,message>
Under-temperature K- <K-degrees,message>
Laser Overcurrent K; <K;message>
Laser Undercurrent K: <K:message>
Power On/Resets Counts K_ <K_powerups,resets>
Time Since Last Reset K@? <K@?hours,minutes> (read only)
Present Operating
Temperature
K%? <K%?deg> (read only)
Click this button to
bring up the
Diagnostic
menu.
To change a setting,
double-click the
setting and use your
curser to scroll
through the options.