Defaulting/Saving/Initializing
MS-820 Industrial Bar Code Scanner User’s Manual A-21
Appendices
Restore Flash Defaults to Active Memory and for Power-on
Caution: Defaulting the scanner to flash default set-
tings will overwrite user-saved NOVRAM settings.
Restores flash defaults to memory.
Restores flash defaults to user-saved NOVRAM
for power-on.
Initializes serial configuration commands in
active memory and resets counters to zero.
By Serial Command
Send <Zd> command to the scanner.
By ESP
1. Right-click in the configuration window and select Default All ESP Settings.
2. Right-click and select Save to Scanner, Send and Save.
By Hardware Default
If a software default reset is not possible, it may be necessary to reset the scanner by
shorting (connecting) specific pins. This procedure has the same effect as the <Zd>
software command.
1. Apply power to the scanner.
2. Locate pins or wires that have continuity to pins4 and8 on the back of the scanner
(see figure A-8 on page A-27). If using an IB-131, locate pins 7 and 11 on the
host connector (see Table A-3 on page A-5).
Caution: Be certain that the correct pins are located. Connecting the wrong
pins could cause serious damage to the unit.
3. Momentarily connect these wires (or pins) and listen for a series of short beeps.
4. Within 3 seconds, connect them again. A longer beep should be heard. If not,
repeat the process.
<Zd>
Flash
Defaults
User-Saved
NOVRAM
Initialize
Active
Memory