Chapter 6 Scanner Setup
MS-820 Industrial Bar Code Scanner User’s Manual 6-3
6–Scanner Setup
Scanner Setup by Serial Command
Note: To save Factory Settings changes to NOVRAM, send <Zp>, or if in ESP, select
Save to Scanner/Advanced/Send and Save, Including Factory. (See “Save
Active Settings including Factory for Power-on” on page -22.)
Command Title comds Format
Scanner Type (factory) KP <KPdensity>
Scan Speed (factory) KE <KEscan speed>
Gain KD <KD gain,AGC mode,AGC min,AGC max>
Transition Counter KH <KH transition counter status,transition counter threshold>
Scanner Setup Status
Request
KU? <KU?>