Serial Verification
8-14 MS-820 Industrial Bar Code Scanner User’s Manual
8–Outputs
Control/Hex Output
Definition: Determines the response to an Serial Command Echo or status
request command.
When set to Control, two characters are transmitted to represent a
non-displayable character. For example, a carriage return will be shown
as the two characters: ^M.
When set to Hex, the output is the hex character.
Usage: Useful for viewing settings with binary characters when using serial
command on a terminal.
Serial Cmd: <KSserial command echo status,serial command beep status,control/
hex output>
Default: Control
Options: 0 = Control 1 = Hex