Appendix K
A-26 MS-820 Industrial Bar Code Scanner User’s Manual
Appendices
Appendix K — Test Decode Rate
With a Static Label
1. Position a stationary bar code in front of a functioning scanner at the scan dis-
tance used in your application.
2. Enter a <C> command to see the decodes per second.
The decode rate is the number of decoded scans per total number of scan. It will
appear at the beginning of the data strings.
Note: You can also enter a <Cp> command to see the percentage of decodes
per scans.
3. Make a note of the decode rate. You will need this when calculating the number of
decodes (see Appendix L — “Formulas for Number of Decodes” on page A-27).
4. End the test by sending the <J> command.
Number of Decodes
To ensure reliable scanning, you need to apply a minimum of five decodes to each bar
code. This means that all variables, label speed, read range, etc. are significant.
Note: Variations between labels are common. For this reason, the greater number of
sample bar codes tested, the more likely you are to achieve optimum decode rates.
In general, the number of decodes of a given bar code can be increased by:
Increasing label height
Decreasing label length
Increasing scan rate (spinning mirror speed)
Slowing label speed
With a Moving Label
Before testing with a moving label, it is highly recommended that you calculate the
expected number of decodes by using the formulas in Appendix L — “Formulas for
Number of Decodes” on page A-27.
Once you’ve mounted the scanner, established a good read rate with a stationary
label, and calculated the number of decodes for your label speed, you can begin
decoding with moving labels.