1-10 MS-820 Industrial Bar Code Scanner User’s Manual
1–Quick Start
Step 9 — Position Scanner and Symbol
Set up a symbol at the scanning distance you will be using in your application.In posi-
tioning the scanner and symbols being scanned, consider the following:
Avoid bright light or IR light from other sources, including other scanners.
Pitch or skew label or scanner a minimum of ±15° to avoid specular reflection, the
return of direct, non-diffused light.
Note: For additional tips on positioning the scanner and bar code labels, see “Position
Scanner and Bar Code” on page A-24.
Code 39 is the default code type enabled. If you are uncertain as to the symbology
type, enable all codes, by clicking the Utilities menu and enabling Autodiscriminate
under Code Types.
0"
22" (558 mm)
20 mil label
15 mil label
10 mil label
19" (483 mm)
16" (406 mm)
12" (305 mm)
10" (254 mm)
7" (178 mm)
6" (152 mm)
5" (127 mm)
4" (102 mm)
30" (762 mm)
40 mil label
20 mil label
5 mil label
il lab
40 mil label
7.5 mil
0"
5.5" (140 mm)
6.75"
(171 mm)
8"
(203 mm)
9"
(229 mm)
4" (102 mm)
3.5"
(89 mm)
3.25"
(82 mm)
3" (76 mm)
15 mil
5mil
10 mil
7.5 mil
5 mil
Figure 1-3 Low Density Ranges Figure 1-4 High Density Ranges
Note: The position of the scanners shown here is simply a
suggested one for quick setup. There are variety of ways
to mount the scanner. The important thing is to keep the
test bar code label and scanner in the same relative posi-
tion as shown here. If your manual is on a CD, look for a
test label on the back of the CD cover.