4-10 MS-2 CCD Reader User’s Manual
Serial Trigger Character (Delimited)
Serial Trigger Character (Delimited)
Note: Serial Data or Serial Data and Edge triggering mode must be
enabled for Serial Trigger Character to take effect.
Usage: Allows the user to define the trigger character and delimiters that start
and stop the read cycle.
Definition: A serial trigger is considered an online host command and requires the
same command format as all host commands. It must be entered within
angle bracket delimiters < > or, in the case of non-delimited triggers, it must
define individual start and stop characters.
Serial Cmd: <K201,serial trigger character>
Default: ^] (<GS>)
Options: Any single ASCII character, including control characters, except NUL (00 in
hex), an existing host command character, or an on-line protocol character.
Control characters entered on the command line are displayed in the menu
as mnemonic characters.