MS-2 CCD Reader User’s Manual 5-13
Symbologies
MSI Code
Status (MSI Code)
Check Character Mode (MSI Code)
Check Character Output Status (MSI Code)
Minimum Symbol Length (MSI Code)
Usage: Used for inventory control and the identification of storage containers and
locations in warehouse environments.
Definition: MSI Code is a numeric, continuous symbology in which each character
consists of four bits in a binary format.
Serial Cmd: <K486,status,check character mode,check character output status,
0,minimum symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: This field is set to perform a Modulus 10 calculation by default. It can also
be set to perform a Double Modulus 10 calculation.
Serial Cmd: <K486,status,check character mode,check character output status,
0,minimum symbol length>
Default: Modulus 10
Options: 1 = Modulus 10 2 = Double Modulus 10
Definition: When this field is enabled, the reader will output the check digit with symbol
data. When disabled, the reader will not output the check digit with symbol
data.
Serial Cmd: <K486,status,check character mode,check character output status,
0,minimum symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition:
This field specifies the minimum number of characters the reader will recognize,
including a check character.
Serial Cmd: <K486,status,check character mode,check character output status,
0,minimum symbol length>
Default: 6
Options: 0 to 32