MS-2 CCD Reader User’s Manual 5-7
Symbologies
Symbol Length (Codabar)
Check Character Status (Codabar)
Check Character Output (Codabar)
Definition: Specifies the number of characters that the reader will recognize, including
start and stop check characters. The
Note: When setting Symbol Length to any value other than 0, add 2 to
account for reserved spaces. For example, if your symbol has 3 characters,
set Symbol Length to 5.
Note: If Symbol Length is set to 0 and Symbol Length Status is set to Any/
Minimum, all symbol lengths are decoded.
Serial Cmd: <K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character status,check character output>
Default: 6
Options: 0 to 32
Definition:
When disabled, the reader will not perform any character checking calculations
on decoded Codabar symbols.
When set to Modulus 16, the reader will perform a Modulus 16 check
character calculation on the symbol. If the symbol does not pass this calculation,
it will not be decoded.
Serial Cmd: <K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character status,check character output>
Default: Disabled
Options: 0 = Disabled
1 = Enabled (Modulus 16)
Definition: When this field is disabled and a check character calculation is enabled, the
reader will strip the verified check character from the symbol data output.
This condition must be accounted for if a minimum length is also being
used.
When enabled, the reader will output the check character as part of the
symbol data. This condition must be accounted for if a minimum length is
also being used.
Serial Cmd: <K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character status,check character output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled